Assembling instruction

¡¡

¡¡

  6EW7 SE amplifier part list.

 

 R1  4K7 

 R2  470K 1W

 R3 470K  1W

 R4 68OHM MOF 2W

 R5 2K2 MOF 1W

 R6 22K MOF 1W

 R7 22K MOF 1W

 R8,R9 560 ohm 5W

 R10,R12 120ohm

 R11, R13, 470K

 R14,R16 4K7

 R15,R17 820K

 

 VR1 100K VR

 DI-D5 UF4007

 C1, C3, 56uF~100uF 400V

 C2 47uF 400V

 C4 82uF 400V

 C5, C6 0.1uF 400V

 C7 22uF~33uF 400V

 C8-C11 100uF 63V

 

 Q1 BUK444 or IRF840

 mosfet with heatsink

 V1,V2, tube sockets.

 

 

 The first thing that you must install are jumpers on pcb, J1 and J2.

 

 Install parts according to the list above, beware of polarity of capacitors, diodes, and FET.

 

 The wall plug must install with 1A fuse or connect a fuse holder with 1A fuse.

 

 The diagram shown is for 230V supply. If your place is 110-115V, please connect the 110V wire to your plug,    disconnect and left open the 230V wire. With 0V wire remains.

 

 Any problem during construction please e-mail me.

 

 

WARNING! Under no circumstances should any reader construct any mains operated equipment unless absolutely sure of his /her abilities in this area. We takes no responsibility for any loss, injury or death howsoever caused resulting from, whether directly or indirectly, the reader's inability to understand and appreciate the hazards of household mains or other voltages as may be applicable to any published material.  All mains wiring should be performed by suitably qualified persons only.